Magnavalves & Controls




















 

 

 

 

 

 

     

Application Notes - Wiring Guides for MagnaValves and Controls

See also Numerical List of Application Notes - below.
(Note: all links are Adobe Acrobat pdf files)
Also available in Deutch

  Control
MagnaValve 102 362a 362a * AC AC-24 FC FC-24 FC + Sensor

FC-24 + Sensor

MC Pot-24 Variac
100       121           120    
1477  162   133     101            
1478 162   133     101            
1479 162   133     101            
1577 160   147     100            
1578 160   147     100            
25       121           120    
250N 161         141            
250P   131       101            
250-24             177          
278 167                      
279 167                      
378     175                  
477 162 102 133     101            
478 162 102 133     101            
479 162 102 133     101            
480 162 102 133     101            
490 162   133     101            
50       121           120    
500N 161         141            
500P   131       101            
500-24             177          
577 160   147     100            
578 160   147     100            
578-24             171          
579 160   147     100            
580 160   147     100            
590 160   147     100            
LP2000 139     137       154   138    
LP2000VAR                       166
LP-24         169       178   168  
VLP1000 139     137       154   138    
VLP1000VAR                       166
VLP-24         169       178   168  
362a* is newer version with stronger power supply
Three versions of AC and FC: (A) original 120 Vac Power, (B) 90-240 Vac Power, (C) 120 Vac Power

Numerical list of Application Notes

App No.

Deutch
Description
Wire connections for 477/478/479/480 to FC Control
Wire connections for 478/479/480 to 362aControl
Wire connections for WA MagnaValve to FC Control (4-s/n's only)
Wire connections for WM MagnaValve to MC Control
Valve Driver Module Selection Guide
Wire connections for model 25/50/100 MagnaValve to MC Control
Wire connections for model 25/50/100 MagnaValve to AC Control
Wheel type MagnaValve Selector Guide
Wire connections for WM MagnaValve to AC Control
Wire connections for 250P/500P to FC Control
Wire connections for 250P/500P to 362a or 362AZ control
22-Terminal connector for 362a Control
Wire connections for 478/479/480 MagnaValve to 362a (version B) Control
Remote set-point pot for multi-flow rates MC/AC/FC Controls
Calibration pots for multi-size shot operation
Wire connections for VLP MagnaValve to AC Control
 Wire connections for VLP/LP MagnaValve to MC Control
Wire connections for VLP MagnaValve to 102 Power Pak
Wire connections for 250N/500N MagnaValve to FC Control
Wire connections for 577/578/579/580 MagnaValve to FC Control
General arrangement for Pressure-Pot type machines
Wire connections for VLP/LP MagnaValve and 599-4.0 sensor and FC Control
General arrangement for Suction type machine (valve below nozzle level)
General arrangement for Gravity-Suction machine (valve above nozzle level)
Wire connections for E.200 to PLC Programmable Logic Control
Wire connections for 599 sensor to PLC Programmable Logic Control
Wire connections for Tealgate E.200 sensor and Action-Pak Relay
Wire connections for 577/578/579/580 MagnaValve to 102 Power Pak and PLC
Wire connections for 250N/500N MagnaValve to 102 Power Pak and PLC
Wire connections for 477/478/479/480 MagnaValve to 102 Power Pak and PLC
Selector Guide MagnaValves used on Air Blast Machines
Bench test fixture for 577/578/479/580 MagnaValves
Wire connections for VLP and 599-4.0 sensor to 102 Power Pak and PLC
Wire connections for VLP1000VAR/LP2000VAR to Variac 0-120 Vac transformer
Wire connections for 278/278 MagnaValve to 102 Power Pak
Wiring connections for LP-24 or VLP-24 to Pot-24 Control or customer's PLC
Wiring connections for LP-24 or VLP-24 to AC-24 Control
Wiring connections for WA-24 MagnaValve to FC-24 Control
Wiring connections for 5xx-24 MagnaValve to FC-24 Control
Maximum Temperature Limits for all EI Products
Do not starve VLP or LP MagnaValves
FC and AC Control Power Supply Problems (120-230 Vac versions only)
Wire Connections for 377/378/379/380/390 to 362a or 362az Controller
Wire Connections for 599-1.25 Sensor to FC-24 Controller
Wire Connections for 250-24 or 500-24 MagnaValve to FC-24 Controller
Wire connections for VLP-24 MagnaValve / 599 Sensor / FC control Hybrid Installation
Proper Installation Technique for airblast sensors and MagnaValves
Valve Driver Replacement Instructions and Bench Power Supply
Using MagnaValves with current sensor feedback with variable speed motor drives for wheel blast machines
Using MagnaValves with built-in flow sensor with variable speed motor drives for wheel blast machines
183   PLC w/servo and MagnaValves with built-in flow sensors and 102 Power Pak (120Vac versions)
184   PLC w/servo and MagnaValves with built-in flow sensors (24Vdc versions)
185   PLC w/servo and MagnaValves for motor amps applications (120Vac versions)
186   PLC w/servo and MagnaValves for motor amps applications (24Vdc versions)